Product Features:
1. Quick elimination of static electricity makes it easier to clean small and sensitive parts and materials
2. Adopt inductive design, ion needle does not electrify people; Separate air flow from high voltage line
3. The effect is good, and it must be integrated with the special high-voltage power supply of Stryker.
4. Ion air gun, the gun body has air volume regulator, and the gun body is made of plastic material, which makes it
feel better
5. It needs to be equipped with ST403A high voltage generator for integrated use
High Voltage Generator Is Required: | |
ST403A One Drag Two/One Drag Four | |
Model Parameters |
ST403A |
Operating power supply | 110V/60HZ or 220V/50HZ |
Consume power supply | 0.23A or 0.12A |
Power | 95W |
Operating temperature range | 0-50℃ |
Weight | 2.25kg |
Length of high voltage cable | 1.5m |
Output voltage | 70KV×2 or 4 |
Output current | 4.5mA |
Can it be used in explosion-proof environment | No |
Model | ST302C |
Ion generation mode | Piezoelectric type |
Material of discharge needle | Wolfram steel |
Host material | ABS fireproof engineering plastics |
Air ion supply range | 8cm~15cm |
Air inlet pipe | Inner diameterΦ8 air duct |
Body size | 260mm(L)×42mm(W)×133mm(H) standard cable length is 2.5m |
Attached belonging products | Instructions/warranty cards/certificates |
Performance | Static removal time <1.5S |
Air consumption | 0.08m³/min |
Noise | 56DB |
Ozone production | <0.02ppm or less (distance 200mm measuring distance) |