1. Needle gauge 25mm, customizable length: 385~410mm
2. Needle gauge 50mm, customizable length: 460~2960mm
Product features
1. With anti-electric shock function, it can prevent electric shock injury to human body
2. Through CE certification, it can effectively avoid the influence of external electromagnetic interference on the
normal operation of Ion Bar
Matters need attention
Technical parameter
Product model | ST-DC-507A |
Input voltage | 220V |
Incoming current | <50mA |
Power | 75W |
Operating voltage | ±7000V |
Ion emission | High frequency AC |
Emitting electrode | SUS |
Gas consumption | 0.05 Cubic meters/minute (below 600mm) |
Discharge structure | Resistance coupling |
Extinguishing range | L * W * H: {385-410 (25mm); in needle gauge); 460-2960 (50mm in needle gauge)} * 300 * 1000mm |
Installation distance | 100→1000mm |
Ionic equilibrium | ≤|±30V|(AVE) |
Power dissipation time | ≤0.1-1.5S |
Airflow pressure | ≤0.7MPa |
With throttle valve Air source connector |
Φ6-G1/8 Blue |
Working temperature | 0℃-50℃ |
Working humidity | <70% |
Outline dimension | L * W * H: {385-410 (25mm); in needle gauge); 460-2960 (50mm in needle gauge)} * 35 * 63.5mm |
Material of rod body | Flame retardant PVC, ABS, AL, SUS |
Installing accessories | Hanging angle can be installed by 180 degree rotation |
Warranty period | 1 Year |
Certification certificate | CE |